China Supplier Rotary Brush Floor Cleaner - GCG1000 Aerosol concentration sensor – Topsky

Short Description:

IntroductionIt is a high-tech sensor developed to meet the requirements of the existing coal mines to monitor the underground dust concentration using the principle of laser scattering. It can monitor and display the underground dust concentration in real-time, on-site, and continuously under na...


Product Detail

Product Tags

Related Video

Feedback (2)

The company upholds the philosophy of "Be No.1 in quality, be rooted on credit and trustworthiness for growth", will continue to serve old and new customers from home and overseas whole-heatedly for Mich Bullet Proof Helmet, Medical Mask With Ear Hook, X-Ray Machine Vision Eod Robot, Looking to the future, a long way to go, constantly striving to become the all staff with full enthusiasm, one hundred times the confidence and put our company built a beautiful environment, advanced products, quality first-class modern enterprise and work hard!
China Supplier Rotary Brush Floor Cleaner - GCG1000 Aerosol concentration sensor – Topsky Detail:

Introduction
It is a high-tech sensor developed to meet the requirements of the existing coal mines to monitor the underground dust concentration using the principle of laser scattering. It can monitor and display the underground dust concentration in real-time, on-site, and continuously under natural air currents, and output and spray water spray at the same time. The switch signal realizes the best effect of dust measurement and dust reduction.

Technical characteristics

(1) The rated working current is small, which greatly reduces the burden of the substation power supply, and can be installed at a position farther away from the substation.

In the case of flow, the rated working current of the whole machine is less than or equal to 120mA, and the maximum working current is less than or equal to 180mA;

(2) The input voltage range is wide, and it can be applied to various substations underground in coal mines. The input voltage of the instrument is 12V~24VDC (intrinsically safe power supply).

Can work normally within the range;

(3) High measurement accuracy: The segmented control algorithm is adopted, and different proportional coefficients are automatically calculated according to different concentrations. At the same time, the temperature compensation function is added to improve the measurement accuracy;

(4) It has the function of automatically calibrating the zero point, and can set the time for calibrating the zero point drift;

(5) It has the function of soft start mode, which reduces the impact on the power supply when the instrument is started, and the maximum start current is ≤130mA;

(6) It has the function of online calibration, which can be directly calibrated online with CCGZ-1000 direct-reading dust detector;

(7) The measurement range can be set to 0-500mg/m3 or 0-1000 mg/m3 as required;

(8) It can measure instantaneous dust concentration or average dust concentration, and the measurement time of average dust concentration can be arbitrarily selected within the range of 1~3600 seconds

General:
GCG1000 Aerosol concentration sensor can calculate the relative mass concentration of dust with the aerosol testing technology. Then through the preset parameter values, ​​it can calculate the mass concentration of dust. Finally through the LCD ,it is converted into a frequency signal or a current signal output.

The sensors can display the coal mine dust concentration continually and real time while 200-1000HZ frequency signal output compatible with the coal mine monitoring systems and 4-20mA current signal for mine monitoring system or other systems. Dust concentration through preset threshold warning point of dust concentration, it immediately outputs a warning signal to alert staff to promptly activate the corresponding dust measures when dust concentration reaches the value measured
1.Specification:

Measuring range 0mg/m3~1000mg/m3
Measuring relative error ±10℅
Sampling flux error 18L/min±2.5℅
Working voltage 12VDC~18VDC
working current ≤200mA
Explosion protection ExibI
Working Temperature O℃~ 40℃
relative humidity ≤95%

2. Delivery kit:
1*GCG1000 Aerosol concentration kit
1*Manual book
1* Factory certification
1*Explosion proof certification
1*Intrinsically safe certification


Product detail pictures:

China Supplier Rotary Brush Floor Cleaner - GCG1000 Aerosol concentration sensor – Topsky detail pictures


Related Product Guide:

Sticking for the principle of "Super Quality, Satisfactory service" ,We have been striving for being a superb small business partner of you for China Supplier Rotary Brush Floor Cleaner - GCG1000 Aerosol concentration sensor – Topsky , The product will supply to all over the world, such as: Puerto Rico, Luxemburg, Poland, Based on experienced engineers, all orders for drawing-based or sample-based processing are welcomed. We have won a good reputation for outstanding customer service among our overseas customers. We will continue to try the best to offer you good quality products and the best service. We are looking forward to serving you.
  • Hope that the company could stick to the enterprise spirit of "Quality, Efficiency, Innovation and Integrity", it will be better and better in the future.
    5 Stars By Gemma from Orlando - 2018.05.15 10:52
    In general, we are satisfied with all aspects, cheap, high-quality, fast delivery and good procuct style, we will have follow-up cooperation!
    5 Stars By Delia Pesina from India - 2017.11.11 11:41
    Write your message here and send it to us